© Nexter 2014 - page 205

Equipment
203
ii
FILTERS
ANTI-RIOT FILTER
MISSION
The anti-riot filter is used for the equipment of
filtration systems like the AFU 60. It ensures
the protection of the respiratory system of
the crew members exposed to tear gas.
This filter can be used against the following
gas types:
• 
Phenacyl chloride (CN),
• 
Benzyl bromide,
• 
2-chlorobenzalmalononitrile (CS Gas).
CHARACTERISTICS
This filter is made up of two filtration levels allowing air purification::
• 
the anti-aerosol level includes a paper layer (class U15 according to EN1822) wich allows our
system to reach the P3 protection capacity,
• 
the anti-vapour level includes an active carbon bed wich allows our system to reach the A1
protection capacity.
PERFORMANCES
Methylene chloride leak rate:
≤ 3.10
-5
Purification coefficient to aerosols (0,15 μm):
> 33,333
Pressure drop of the new filter:
< 600Pa to 70m
3
/h
Protection capacity:
A1 according to EN 14387 standard
1...,195,196,197,198,199,200,201,202,203,204 206,207,208,209,210,211,212,213,214,215,...236